A hole the size of a pound coin is enough
A cable passes through a compartment wall above a corridor ceiling in a care home. The hole drilled for it is a few centimetres wider than the cable, and that gap has never been sealed. In a fire, that unsealed penetration lets smoke and hot gases pass from one compartment into the next within minutes. The residents in the adjoining wing were never supposed to be exposed to that fire. The fire stopping was meant to stop it. There wasn't any.
This is the quiet failure that undermines fire safety in care homes more than almost anything else. The fire doors can be perfect. The alarm can work flawlessly. But if the compartment walls and floors are breached by unsealed holes, the protection they were designed to provide has already gone.
What fire stopping actually is
A care home is divided into fire compartments — walls and floors built to resist fire for a set period, often 30 or 60 minutes, so that a fire starting in one area is held there long enough for people to be moved or for the fire service to arrive. That resistance only holds if the compartment is sealed. Every time a service is run through a wall or floor — a cable, a pipe, a duct — a hole is made. Fire stopping is the material that seals those holes so the barrier performs as designed.
The products are specific: intumescent sealants that expand under heat, fire-rated pillows, collars that crush a plastic pipe shut, batt and mastic systems. Each is tested and certified for a particular wall or floor type and a particular service passing through it. A collar rated for a 110mm plastic pipe will not do the job on a bundle of cables. Fit the wrong product, or fit the right product badly, and the seal is worthless.
Why care homes carry more risk than most buildings
Stay put does not work the same way in a care home. Many residents cannot walk to an exit, cannot respond quickly to an alarm, and depend entirely on staff to move them. Evacuation is slow. That slowness is precisely why compartmentation — and the fire stopping that keeps it intact — matters so much. The barriers have to buy enough time for staff to move people who cannot move themselves.
Care homes are also constantly altered. New nurse-call systems, extra power points, upgraded heating, additional data cabling — every one of those works punches through compartment walls and ceilings. If the contractor who ran the cable did not reinstate the fire stopping, and nobody checked, you now have a breach. These works are often done quietly, out of hours, by trades who have no idea they have just compromised a fire barrier.
What the law expects of you
Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person must ensure the general fire precautions in the building are maintained in an effective state. Compartmentation is a general fire precaution. The Building Safety Act 2022 and the Fire Safety (England) Regulations 2022 have sharpened the duty to understand and record the condition of the building's fire protection — the golden thread of information about what is there and whether it works.
In practice, that means you cannot assume your compartments are sound. You need evidence. A compartmentation survey inspects the walls, floors and the hidden voids above ceilings and below floors, and identifies where fire stopping is missing, wrong or damaged. For a care home, that survey is not a box-ticking exercise — it is how you find out whether the barriers your residents depend on actually exist.
Where the breaches hide
The gaps are almost never visible from the corridor. Lift the ceiling tile and you find the real picture: service risers packed with unsealed cables, holes around pipework left open by a plumber, batt that has shrunk and pulled away from the wall, old penetrations abandoned but never filled. Riser cupboards, plant rooms and the voids above suspended ceilings are where fire stopping most often fails, because nobody looks there between surveys.
What to do
Get a compartmentation survey carried out by a competent contractor, ideally one holding third-party certification for passive fire protection. Keep the report, the remedial schedule and the certificates for any fire stopping installed — that is your evidence and part of your golden thread. Then control change: build fire stopping reinstatement into the specification of any works that penetrate a wall or floor, and inspect before the ceiling goes back up. A sealed compartment is only sealed until the next contractor opens it.