The duct you've never seen is coating itself in fuel
A care home kitchen plates up breakfast, lunch and dinner every day of the year. Fry, grill, roast, repeat. Every one of those meals pushes warm, fat-laden air up through the canopy and into the extract ductwork — and a thin film of grease settles on the inside of that ducting with every service. You don't see it, because it sits behind the canopy, above the ceiling, running through voids and out to a fan on the roof. Out of sight, and in most homes, out of mind.
That grease is fuel. A kitchen fire that reaches a greasy duct doesn't stay in the kitchen. It travels the length of the ductwork, carrying flame through compartments that were designed to hold it back. In a building where your residents cannot get themselves out, that is precisely the scenario your whole fire strategy is built to prevent.
What TR19 Grease actually asks of you
TR19 Grease is the industry standard — published by BESA — for cleaning kitchen extract systems. It isn't a law in itself, but it's the recognised benchmark for how the job should be done, and it's the standard your insurer and fire risk assessor will expect you to meet. When something goes wrong, "we had it cleaned" is not a defence. "We had it cleaned to TR19 Grease and here is the report" is.
The core of it is straightforward. The system has to be cleaned along its whole accessible length — canopy, filters, plenum, ductwork and extract fan — not just the bits a cloth can reach. Grease deposits are measured, and the system is cleaned until it meets an acceptable level. Access panels have to be fitted where there aren't any, because you cannot clean or verify a duct you can't get into. And the whole thing is recorded with before-and-after photographs and a report that states what was cleaned, what wasn't reachable, and when it's next due.
That last point matters. Where a section of duct can't be accessed, TR19 Grease expects it to be flagged — not quietly skipped. A report that shows 100% clean with no mention of access is often a report that only covered the easy parts.
How often, and why "once a year" isn't an answer
Cleaning frequency is driven by how hard the kitchen works. A care home kitchen running heavy use — multiple hot meals, frying and grilling daily — falls into the higher-usage bracket and typically needs cleaning more often than a light-use kitchen that only reheats. TR19 Grease sets out risk-based frequencies tied to hours of cooking per day. The honest answer is that your frequency should be set by a competent assessment of your kitchen's output, not by a round number plucked from a renewal diary.
Under the Regulatory Reform (Fire Safety) Order 2005, the Responsible Person has to manage fire risk in the premises. A grease-laden extract system is a fire risk, and a known one. Letting it build up isn't a maintenance oversight — it's a gap in your fire safety management that a fire risk assessment should pick up and that an inspector can hold you to.
A scenario you'll recognise
A residential care home had its kitchen "deep cleaned" every quarter by its catering contractor. The canopy gleamed. Then a fire risk assessment reviewed the extract system properly and found the ductwork above the ceiling had never been opened — there were no access panels fitted at all. The quarterly clean had wiped down everything visible and nothing beyond it. Years of grease sat in a horizontal run of duct passing directly over a corridor used as an escape route.
The fix wasn't dramatic: access panels installed at the right intervals, a full TR19 Grease clean, and a report setting a frequency matched to the kitchen's actual use. But the point stands — the home genuinely believed it was compliant, and it wasn't. The paperwork said "cleaned". The duct said otherwise.
What to ask for and keep
Get a TR19 Grease report after every clean. Check it names the whole system, flags any sections that couldn't be reached, includes photographs, records grease measurements and sets the next due date. Keep those reports with your fire safety documentation — they're part of demonstrating you've managed the risk, and they sit alongside your fire damper and compartmentation records as evidence the Responsible Person did their job.
If the extract runs through a fire-rated wall or floor, a fire damper usually sits in that duct — and it needs cleaning and testing too, because grease stops a damper closing. Extract hygiene and passive fire protection aren't separate problems. In a care home, they're the same problem seen from two ends of the same duct.